RUSH MH 4 Beam User Manual 5
For the latest user documentation and other information about
this and all Martin™ products, please visit the Martin website at
http://www.martin.com
Protection from electric shock
Do not expose the fixture to rain or moisture.
Shut down power to the fixture before carrying out any
installation or maintenance work and when the fixture is not in
use.
Ensure that the fixture is electrically connected to ground
(earth).
Use only a source of AC power that complies with local building
and electrical codes and has both overload and ground-fault
(earth-fault) protection.
Socket outlets or external power switches used to supply the
fixture with power must be located near the fixture and easily
accessible so that the fixture can easily be disconnected from
power.
Disconnect the fixture from AC power before removing or
installing any cover or part and when not in use.
Replace defective fuses with ones of the specified type and
rating only.
Isolate the fixture from power immediately if the power plug or
any seal, cover, cable, or other component is damaged,
defective, deformed, wet or showing signs of overheating. Do
not reapply power until repairs have been completed.
Before using the fixture, check that all power distribution
equipment and cables are in perfect condition and rated for the
current requirements of all connected devices.
Use only Neutrik PowerCon cable connectors to connect to
power sockets.
Do not connect devices to power in a chain that will exceed the
electrical ratings of any cable or connector used in the chain.
The supplied power input cable is rated 6 A and can safely
supply only one fixture with mains power. Do not connect any
device to the fixture’s MAINS OUT connector when using this
cable. If you replace this cable and also use the replacement
cable to supply only one fixture with mains power, the